E2E-IL

Funktioner

IO-Link-standardafstandssensorer som den innovative løsning til problemer på industrielle produktionsanlæg.

  • Nedetid kan reduceres gennem interne diagnosticeringsfunktioner 
  • Pludselige svigt kan reduceres ved underretning om, hvorvidt genstande er for langt væk eller for tæt på
  • Vedligeholdelsen er mere effektiv gennem identifikation af den enkelte sensor via IO-Link-netværket.
  • Programmerbar betjening af sensoren reducerer antallet af modeller
Specifikationer & bestillingsinfo

Ordering information

DC 3-wire IO-Link models

Appearance

Sensing distance

Connection method

Cable specifications

Operation mode

Pin arrangement

Baud rate

Order code

PNP

 

M12

3 mm

Pre-wired models (2 m)

PVC
(oil-resistant)

NO/NC
switching

COM2

E2E-X3B4-IL2 2M

COM3

E2E-X3B4-IL3 2M

M12 Pre-wired Smartclick connector models (0.3 m)

1: +V

3: 0 V

4: C/Q output

COM2

E2E-X3B4-M1TJ-IL2 0.3M

COM3

E2E-X3B4-M1TJ-IL3 0.3M

M18

7 mm

Pre-wired models (2 m)

COM2

E2E-X7B4-IL2 2M

COM3

E2E-X7B4-IL3 2M

M12 Pre-wired Smartclick connector models (0.3 m)

1: +V

3: 0 V

4: C/Q output

COM2

E2E-X7B4-M1TJ-IL2 0.3M

COM3

E2E-X7B4-M1TJ-IL3 0.3M

M30

10 mm

Pre-wired models (2 m)

COM2

E2E-X10B4-IL2 2M

COM3

E2E-X10B4-IL3 2M

M12 Pre-wired Smartclick connector models (0.3 m)

1: +V

3: 0 V

4: C/Q output

COM2

E2E-X10B4-M1TJ-IL2 0.3M

COM3

E2E-X10B4-M1TJ-IL3 0.3M

Specifications

DC 3-wire IO-Link models (E2E-X_B4-IL_)

Size

M12

M18

M30

Shielded

Shielded

Item

Model

E2E-X3B4-IL_

E2E-X7B4-IL_

E2E-X10B4-IL_

Sensing distance

3 mm ±10%

7 mm ±10%

10 mm ±10%

Set distance1

0 to 2.4 mm

0 to 5.6 mm

0 to 8 mm

Differential travel

10% max. of sensing distance

Response frequency2

1 kHz

0.5 kHz

0.4 kHz

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p))

Current consumption

20 mA max.

Control output

Load current

100 mA max.

Residual voltage

2 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators1

In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability indicator (green, lit)

In the IO-Link mode: Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)

Operation mode

PNP NO/NC switching type (Factory setting: NO)

Degree of protection

IEC 60529 IP67, in-house standards: oil-resistant3

Connection method

Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m)

Materials

Case

Nickel-plated brass

Sensing surface

PBT

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Main IO-Link functions

Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, and initial reset

Communication specifications

IO-Link specification

Ver 1.1

Baud rate

-IL3: COM3 (230.4 kbps), -IL2: COM2 (38.4 kbps)

Data length

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)

Minimum cycle time

-IL3 (COM3): 1 ms, -IL2 (COM2): 2.3 ms

 


1. In the Standard I/O mode (SIO mode), use the product in a range that the green stability indication lamp is lit. (Although the lamp is turned off when the object detected has approached excessively, the detection performance is stable.)
In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.)
Please contact your OMRON sales representative regarding assignment of data.
2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
3. Oil resistance in-house standard: Performance with respect to water insoluble oil. (Test at right)
1. In the Standard I/O mode (SIO mode), use the product in a range that the green stability indication lamp is lit. (Although the lamp is turned off when the object detected has approached excessively, the detection performance is stable.)
In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.)
Please contact your OMRON sales representative regarding assignment of data.
2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
3. Oil resistance in-house standard: Performance with respect to water insoluble oil. (Test at right)
Tilbehør

XS2

XS2_OEI.jpg
Ledningssæt med XS2-stik med vandtætte M12-forlængerledningssæt med enkeltende

XS3

XS3_OEI.jpg
XS3-ledningssæt med M8-forlængerledningssæt med enkeltende for reduceret vedligeholdelse.

XS5C/XS5G

XS5C_XS5G_400x400.jpg
XS5C/XS5G-D418-stik af IDC-typen er specielt udviklet til hurtig og nem tilslutning uden brug af specialværktøj.

Y92E-S_PP

Y92E-S_OEI.jpg
IP69K Nominel ledningssæt til sensorstik til anvendelser inden for levnedsmiddel- og lægemiddelindustrien

Har du et spørgsmål?

Vi er klar til at hjælpe.

Kontakt os

Abonnér på produktopdateringer

Nyhedsbreve om produktinnovationer, løsninger og serviceydelser direkte i din indbakke.

Tak for din tilmelding til Omrons nyhedsbrev. Du vil i løbet af kort tid modtage en e-mail fra os, som indeholder et link hvormed du aktiverer din tilmelding til nyhedsbrevet. Denne metode anvendes i henhold til lovgivningen for at sikre, at ingen kan misbruge din e-mail addresse.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Produktdokumentation

Download datablade, manualer og brochurer.

Gennemse downloadcenter

Kurser

Bliv uddannet af vores bedste ingeniører. Fra begynder til udvidet niveau.