E3Z-_-IL

Funktioner

IO-Link-sensor i kompakt plastkabinet

Takket være IO-Links funktionaliteter giver E3Z IO-Link-sensoren høj funktionalitet og nem adgang til data. Sensoren er designet i kompakt kabinetstørrelse med avanceret diagnosticering, fleksible indstillinger og alle standard detekteringstilstande og er derfor det foretrukne valg inden for standard- og krævende applikationer.

  • Konfiguration og kommunikation via IO-Link v1.1
  • IO-Link-funktionaliteter med avanceret diagnosticering
  • Overførselshastighed COM 2 og COM 3
  • Robust og kompakt kabinet
Specifikationer & bestillingsinfo

Ordering information

 

Sensor type

Sensing distance

Baud rate

Connection method

Order code

 

 

 

 

PNP output

Through-beam

(Emitter + Receiver)1

15 m

(Infrared light)

COM2

-

-

2 m

-

E3Z-T81-IL2 2M

Emitter:

E3Z-T81-L-IL2 2M

Receiver:

E3Z-T81-D-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-T81-M1TJ-IL2 0.3M

Emitter:

E3Z-T81-L-M1TJ-IL2 0.3M

Receiver:

E3Z-T81-D-M1TJ-IL2 0.3M

-

-

-

E3Z-T86-IL2

Emitter:

E3Z-T86-L-IL2

Receiver:

E3Z-T86-D-IL2

COM3

-

-

2 m

-

E3Z-T81-IL3 2M

Emitter:

E3Z-T81-L-IL3 2M

Receiver:

E3Z-T81-D-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-T81-M1TJ-IL3 0.3M

Emitter:

E3Z-T81-L-M1TJ-IL3 0.3M

Receiver:

E3Z-T81-D-M1TJ-IL3 0.3M

-

-

-

E3Z-T86-IL3

Emitter:

E3Z-T86-L-IL3

Receiver:

E3Z-T86-D-IL3

Retro-reflective with

MSR function2

4 m (100 mm)3

(Red light)

COM2

-

-

2 m

-

E3Z-R81-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-R81-M1TJ-IL2 0.3M

-

-

-

E3Z-R86-IL2

COM3

-

-

2 m

-

E3Z-R81-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-R81-M1TJ-IL3 0.3M

-

-

-

E3Z-R86-IL3

Diffuse-reflective

1 m

(Infrared light)

COM2

-

-

2 m

-

E3Z-D82-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-D82-M1TJ-IL2 0.3M

-

-

-

E3Z-D87-IL2

COM3

-

-

2 m

-

E3Z-D82-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-D82-M1TJ-IL3 0.3M

-

-

-

E3Z-D87-IL3

90 mm (narrow beam)

(Red light)

COM2

-

-

2 m

-

E3Z-L81-IL2 2M

-

-

-

⬛ M12, 0.3 m

E3Z-L81-M1TJ-IL2 0.3M

-

-

-

E3Z-L86-IL2

COM3

-

-

2 m

-

E3Z-L81-IL3 2M

-

-

-

⬛ M12, 0.3 m

E3Z-L81-M1TJ-IL3 0.3M

-

-

-

E3Z-L86-IL3

Note: Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).

Specifications

 

 

Sensing method

Through-beam

Retro-reflective
with MSR function

Diffuse-reflective

Narrow-beam Models

 

PNP
output

Pre-wired

E3Z-T81-IL_

E3Z-R81-IL_

E3Z-D82-IL_

E3Z-L81-IL_

Model

Pre-wired
connector (M12)

E3Z-T81-M1TJ-IL_

E3Z-R81-M1TJ-IL_

E3Z-D82-M1TJ-IL_

E3Z-L81-M1TJ-IL_

Item

Connector (M8)

E3Z-T86-IL_

E3Z-R86-IL_

E3Z-D87-IL_

E3Z-L86-IL_

Directional angle

Both emitter and receiver: 3 to 15 °

2 to 10 °

-

Light source (wavelength)

Infrared LED (870 nm)

Red LED (660 nm)

Infrared LED (860 nm)

Red LED (650 nm)

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p))

Protection circuits

Reversed power supply polarity protection, output short-circuit protection, and reversed output polarity protection

Reversed power supply polarity protection, output short-circuit protection,
reversed output polarity protection, and mutual interference prevention

Response time

Operate or reset: 1 ms max.

Ambient temperature range

Operating: −25 to 55°C (with no icing or condensation)
Storage: 40 to 70 ° C (with no icing or condensation)

Degree of protection

IEC 60529 IP67

Material

Case

Polybutylene terephthalate (PBT)

Display

Modified polyarylate

Lens

Modified polyarylate

Methacrylate resin (PMMA)

Modified polyarylate

Main IO-Link functions

Operation mode switching between Light ON and Dark ON, setup of the instability detection level for light receiving and non-light receiving, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting, setup of a teaching level and execution of teaching, setup of light receiving sensitivity level, monitor output, operating hours read-out, and initial reset

Communication specifications

IO-Link specification

Ver 1.1

Baud rate

  • IL3: COM3 (230.4 kbps),
  • IL2: COM2 (38.4 kbps)

Data length

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)

Minimum cycle time

  • IL3 (COM3): 1 ms,
  • IL2 (COM2): 2.3 ms

 

Light incident level monitor prevents false detection before it happens


1. Through-beam sensors are normally sold in sets that include both the Emitter and Receiver.

2. The Reflector is sold separately. Select the Reflector model most suited to the application.

3. The sensing distance specified is possible when the E39-R1S is used. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.

1. Through-beam sensors are normally sold in sets that include both the Emitter and Receiver.

2. The Reflector is sold separately. Select the Reflector model most suited to the application.

3. The sensing distance specified is possible when the E39-R1S is used. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.

Kabler og tilbehør

XS2

XS2_OEI.jpg
Ledningssæt med XS2-stik med vandtætte M12-forlængerledningssæt med enkeltende

XS3

XS3_OEI.jpg
XS3-ledningssæt med M8-forlængerledningssæt med enkeltende for reduceret vedligeholdelse.

XS5C/XS5G

XS5C_XS5G_400x400.jpg
XS5C/XS5G-D418-stik af IDC-typen er specielt udviklet til hurtig og nem tilslutning uden brug af specialværktøj.

Y92E-S_PP

Y92E-S_OEI.jpg
IP69K Nominel ledningssæt til sensorstik til anvendelser inden for levnedsmiddel- og lægemiddelindustrien

Har du et spørgsmål?

Vi er klar til at hjælpe.

Kontakt os

Abonnér på produktopdateringer

Nyhedsbreve om produktinnovationer, løsninger og serviceydelser direkte i din indbakke.

Tak for din tilmelding til Omrons nyhedsbrev. Du vil i løbet af kort tid modtage en e-mail fra os, som indeholder et link hvormed du aktiverer din tilmelding til nyhedsbrevet. Denne metode anvendes i henhold til lovgivningen for at sikre, at ingen kan misbruge din e-mail addresse.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Produktdokumentation

Download datablade, manualer og brochurer.

Gennemse downloadcenter

Kurser

Bliv uddannet af vores bedste ingeniører. Fra begynder til udvidet niveau.

Se tilgængelige kurser