E3NX-CA

Funktioner

Højtydende farvemærkesensor

E3NX-CA giver pålidelig detektering af farvemærker til både standardapplikationer og udfordrende applikationer. Konfigurationen med det separate sensorhoved giver mulighed for nem tilpasning til monteringskravene, selv når pladsforbruget er afgørende.
  • Kapacitet til at skelne mellem meget små farveforskelle
  • Svarhastighed på 50 μs med kontrasttilstand
  • Bank skifte for op til 8 banke
  • RGB-datatransmissionsfunktion
  • Nem indlæring med Smart Tuning inden for få sekunder
  • EtherCAT-kommunikationsenhed til forbindelse til højhastighedsbus
Specifikationer & bestillingsinfo

Ordering information

 

Type

Appearance

Connecting method

Inputs/outputs

Order code

NPN output

PNP output

Standard models

 

Pre-wired (2 m)

1 output

E3NX-CA11 2M

E3NX-CA41 2M

 

Wire-saving Connector

1 output

E3NX-CA6

E3NX-CA8

Advanced models

 

Pre-wired (2 m)

2 outputs + 1 input

E3NX-CA21 2M

E3NX-CA51 2M

Model for Sensor Communications Unit1

 

Connector for Sensor Communications Unit

-

E3NX-CA0

Specifications

 

Item

Type

Standard models

Advanced models

Model for Sensor Communications Unit 1

NPN output

E3NX-CA11

E3NX-CA6

E3NX-CA21

E3NX-CA0

PNP output

E3NX-CA41

E3NX-CA8

E3NX-CA51

Connecting method

Pre-wired

Wire-saving Connector

Pre-wired

Connector for Sensor Communications Unit

I/O

Outputs

1 output

2 outputs

- 2

External input

-

1 input3

Light source (wavelength)

White LED (420 to 700 nm)

Supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Supplied from the connector through the Sensor Communications Unit.

Power consumption4

At Power Supply Voltage of 24 VDC

Normal mode: 960 mW max. (Current consumption: 65 mA max.)

Eco function ON: 720 mW max. (Current consumption: 30 mA max.)

Eco function LO: 800 mW max. (Current consumption: 33 mA max.)

Control output

Load power supply voltage

30 VDC max., open-collector output

-

Load current

Groups of 1 to 3 Amplifiers: 100 mA max.,

Groups of 4 to 30 Amplifiers: 20 mA max.

Residual voltage

At load current of less than 10 mA: 1 V max.

At load current of 10 to 100 mA: 2 V max.

OFF current

0.1 mA max.

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection

Power supply reverse polarity protection

Sensing method

Contrast Mode: Light intensity discrimination for RGB (initial state/after 2-point tuning) (R+G+B light intensity discrimination for 1-point tuning)

Color Mode: RGB ratio discrimination

Response time

Super-high-speed Mode (SHS)5

Operate or reset: 50 µs (only in Contrast Mode)

High-speed Mode (HS)

Operate or reset: 250 µs

Standard Mode (Stnd)

Operate or reset: 1 ms

Giga-power Mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full autotuning, or 1-point tuning (1% to 99%)) or manual adjustment

Maximum connectable units

30 Units

30 Units (When connected to OMRON NJ-series Unit)

Functions

Operation mode

Contrast Mode: NO (Light-ON) or NC (Dark-ON)

Color Mode: NO (ON for match: ON for same color as registered color) or NC (ON for mismatch: ON for different color from registered color)

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer (Counted by 0.1 s in a range of 0.1 to 0.5 ms, by 0.5 ms for 0.5 to 5 ms, and by 1 ms for 5 to 9999 ms. Default: 10 ms, Error: 0.1 ms)

Zero reset

Contrast Mode only

Negative values can be displayed. (Threshold level is shifted.)

Resetting settings6

Select from initial reset (factory defaults), user reset (saved settings), or bank reset.

Eco mode

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching

Select from banks 1 to 8.

Power tuning level

Set from 100 to 9,999. (The RGB maximum incident level at Smart Tuning is adjusted to the power tuning level.)

Output 2

-

Normal, error output, AND output, or OR output

-

External input

-

Select from input OFF, tuning, full-auto tuning, emission OFF, bank 1 and 2 switching, bank 1 through 8 switching, or zero reset.

-

Changing the displays

Threshold level and incident level, channel number and incident level, RGB display and incident level, or bank display and incident level

*1 The E3NW-ECT Sensor Communications Unit can be used, but the E3NW-CRT/CCL, E3X-DRT21-S, and E3X-CRT/ECT Sensor Communications Units cannot be used.

*2 Two sensor outputs are allocated in the programmable logic controller (PLC) I/O table. PLC operation via Communications Unit enables reading detected values and changing settings.

*3 The following details apply to the input.

 

Contact input (relay or switch)

Non-contact input (transistor)

NPN

ON: Shorted to 0 V (Sourcing current: 2 mA max.).

OFF: Open or shorted to Vcc.

ON: 1.5 V max. (Sourcing current: 2 mA max.)

OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)

PNP

ON: Shorted to Vcc (Sinking current: 3 mA max.).

OFF: Open or shorted to 0 V.

ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)

OFF: 1.5 V max. (Leakage current: 0.1 mA max.)

*4 Power consumption
At Power Supply Voltage of 10 to 30 VDC
Normal mode: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 74 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 50mA max. at 10 VDC)
Eco function LO: 930 mW max. (Current consumption: 31 mA max. at 30 VDC, 55 mA max. at 10 VDC)

*5 The mutual interference prevention function is disabled if the detection mode is set to Super-high-speed Mode.

*6 The bank is not reset by the user reset function or saved by the user save function.

Recommended fiber heads

Sensing method

Appearance

Sensing direction

Size

Order code

Reflective

 

Right-angle

M6

E32-C91N 2M

Through-beam

(Grooved type)

 

Array

10 mm

E32-G16 2M

Fiber amplifier connectors

Type

Appearance

Cable length

No. of conductors

Applicable fiber amplifier units

Order code

Master connector

 

2 m

3

E3NX-CA6

E3NX-CA8

E3X-CN11

Slave connector

 

1

E3X-CN12

 


1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.

*1 The E3NW-ECT Sensor Communications Unit can be used, but the E3NW-CRT/CCL, E3X-DRT21-S, and E3X-CRT/ECT Sensor Communications Units cannot be used.

*2 Two sensor outputs are allocated in the programmable logic controller (PLC) I/O table. PLC operation via Communications Unit enables reading detected values and changing settings.

*3 The following details apply to the input.

*4 Power consumption
At Power Supply Voltage of 10 to 30 VDC
Normal mode: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 74 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 50mA max. at 10 VDC)
Eco function LO: 930 mW max. (Current consumption: 31 mA max. at 30 VDC, 55 mA max. at 10 VDC)

*5 The mutual interference prevention function is disabled if the detection mode is set to Super-high-speed Mode.

*6 The bank is not reset by the user reset function or saved by the user save function.

1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.

Anvendelse

Registreringsmærker

Det emballagemateriale, der anvendes i mange emballeringsmaskiner, leveres meget ofte i ruller og skal skæres til og positioneres præcist. For at undgå spild og fejl og for at kompensere for miljømæssige påvirkninger tilføjes der et registreringsmærke (normalt sort eller i en farve, der giver maksimal kontrast til baggrunden) på emballagen.

Formålet med enhver mærkningssensor er pålidelig detektering af disse registreringsmærker selv i skiftende omgivelser. En særlig udfordring er den hyppige udskiftning af emballagematerialer og de stadig skiftende emballagedesign.

Hos Omron arbejder vi tæt sammen med førende producenter af emballeringsmaskiner med henblik på at evaluere kravene til aftastere fra gængse emballagematerialer såvel som de mest kritiske design eller materialer. Desuden varierer præstationskravene i forhold til det samlede maskinværdikoncept.

Løsningsportefølje

Kompleks detektering af formgivning og position samt synkroniseret inspektion i høj kvalitet

I forbindelse med positionering og maskinsynkroniseringsopgaver, der f.eks. kræver genkendelse af ord eller symboler, kan formgivnings- og positionsdetekteringsfunktionerne for vision sensorer og systemer konfigureres til at levere løsninger til de mest komplicerede og udfordrende opgaver. Vision systemerne kan også detektere registreringsmærket og udføre positions og kvalitetsinspektion samtidigt.
  • FQ2 - Intuitiv brugerflade og krystalklare billeder
  • Xpectia-Lite - høj ydeevne kombineret med enkelhed
proplus_long.jpg

Udfordrende design eller farvemærker

Objekter med komplicerede design, eller hvor der eksisterer lav kontrast mellem trykmærker og baggrund, kræver sensorer, der muliggør nem tilpasning til specifikke krav for den pågældende opgave.
  • Forstærkere med visning af digitale værdier og avanceret signalevalueringsfunktioner af hensyn til applikationsoptimerede indstillinger
  • Bredt udvalg af sensorhoveder, der passer til applikations- og afstandskravene
  • Hvid LED, sammenligning af RGB farver og udvidet funktionalitet
Color_Mark_Sensors_Teaser_373x140.jpg

Detektering af standardtrykmærker

For de trykmærker, der oftest anvendes i emballerings- og udskrivningsbranchen, har kontrastsensorerne med hvid LED optimeret lysintensitet og evalueringsalgoritme til RGB farver, hvilket sikrer stabil og hurtig detektering.
  • Kompakt kabinetkoncept, der sikrer høj fleksibilitet inden for maskindesign
  • Hurtig responstid på 50 μs
E3ZM-V
  • Automatisk programmering og hvid LED
For yderligere oplysninger henvises til E3ZM-V
lite_long.jpg

Har du et spørgsmål?

Vi er klar til at hjælpe.

Kontakt os

Abonnér på produktopdateringer

Nyhedsbreve om produktinnovationer, løsninger og serviceydelser direkte i din indbakke.

Tak for din tilmelding til Omrons nyhedsbrev. Du vil i løbet af kort tid modtage en e-mail fra os, som indeholder et link hvormed du aktiverer din tilmelding til nyhedsbrevet. Denne metode anvendes i henhold til lovgivningen for at sikre, at ingen kan misbruge din e-mail addresse.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Produktdokumentation

Download datablade, manualer og brochurer.

Gennemse downloadcenter

Kurser

Bliv uddannet af vores bedste ingeniører. Fra begynder til udvidet niveau.

Se tilgængelige kurser