Login

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Register

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Thank you for your interest

You now have access to H3DT

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

H3DT

H3DT

DIN 17.5-mm-wide slim timers with Push-in plus Technology for in-panel applications

  • Helps save space and reduces work in control panels
  • Slim timers (17.5-mm width) with two sets of contacts: One of the slimmest timers worldwide
  • Reduces power consumption (active power) by up to 60% to help reduce heat generation in control panels
  • Certified for maritime standards (LR/DNV GL)
  • RoHS compliant

Specifications & ordering info

Ordering information

Type

Supply voltage

Operating modes

Terminal block

Input type

Control output

Time range

Order code

Multi-range, multi-mode standard timer

24 to 240 VAC/DC

A2 : ON Delay (Power ON Delay)

B3 : Flicker OFF Start (Power ON Start)

B4 : Flicker ON Start (Power ON Start)

D : Signal OFF Delay

E2 : Interval (Power ON Start)

E3 : Signal OFF Interval

F2 : Cumulative (ON Delay)

F3 : Cumulative (Interval)

10 terminals

Voltage input

Relay, DPDT

0.1 s to 1,200 h

H3DT-N2

8 terminals

Relay, SPDT

H3DT-N1

Multi-range, multi-mode expansion timer

A : ON Delay (Signal ON Delay)

B : Flicker OFF Start (Signal Start)

B2 : Flicker ON Start (Signal Start)

C : Signal ON/OFF Delay

E : Interval (Signal Start)

G : Signal ON/OFF Delay

J : One-shot Output (Signal Start)

J2 : One-shot Output (Power ON Start)

10 terminals

Relay, DPDT

H3DT-L2

8 terminals

Relay, SPDT

H3DT-L1

Power ON-delay timer

24 to 240 VAC/DC

Power ON-delay

8 terminals

-

Relay, DPDT

0.1 s to 1,200 h

H3DT-A2

6 terminals

Relay, SPDT

H3DT-A1

Twin timer

24 to 240 VAC/DC

Flicker OFF start/flicker ON start

6 terminals

-

Relay, SPDT

0.1 s to 1,200 h

H3DT-F

Star-delta timer

24 to 240 VAC/DC

Time-limit operation/self-resetting

8 terminals

-

Relay, Time-limit

Star circuit, SPDT

Delta circuit, SPDT

1 to 120 s4

H3DT-G

Power OFF-delay Timer

100 to 120 VAC

Instantaneous operation/time-limit reset

6 terminals

-

Relay, SPDT

0.1 to 12 s

H3DT-HCS

200 to 240 VAC

H3DT-HDS

24 to 48 VAC/DC

H3DT-HBS

100 to 120 VAC

1 to 120 s

H3DT-HCL

200 to 240 VAC

H3DT-HDL

24 to 48 VAC/DC

H3DT-HBL

Specifications

 

H3DT

-N2/-L2

-N1/-L1

-A2

-A1

-F

-G

-HCS

-HCL

-HDS

-HDL

-HBS/-HBL

Power supply voltage

24 to 240 VAC/DC, 50/60 Hz 5 , 6

100 to 120 VAC, 50/60 Hz

200 to 240 VAC, 50/60 Hz

24 to 48 VAC/DC, 50/60 Hz2

Allowable voltage fluctuation range

85% to 110% of rated voltage

Power reset

Minimum power-OFF time: 0.1 s

-

Reset voltage

10% of rated voltage

-

Voltage input

24 to 240 VAC/DC
High level:
20.4 to 264 VAC/DC,
Low level: 0 to 2.4 VAC/DC

-

Power consumption

At 240 VAC: 2.3 VA max.,
at 240 VDC: 1.0 W max.,
at 24 VDC: 0.3 W max.7

At 240 VAC: 2.0 VA max.,
at 240 VDC: 0.9 W max.,
at 24 VDC: 0.3 W max.3

At 240 VAC: 2.2 VA max.,
at 240 VDC: 0.7 W max.,
at 24 VDC: 0.3 W max.3

At 240 VAC: 1.8 VA max.,
at 240 VDC: 0.6 W max.,

at 24 VDC: 0.3 W max.3

At 240 VAC: 1.9 VA max.,
at 240 VDC: 0.6 W max.,
at 24 VDC: 0.3 W max.

At 120 VAC: 8.7 VA max.

At 120 VAC: 8.8 VA max.

At 240 VAC: 21.6 VA max.

At 240 VAC: 21.7 VA max.

At 48 VAC: 1.0 VA max.,
at 24 VDC: 0.4 W max.

Control output

Contact output:

  • 5 A at 250 VAC with resistive load (cosφ = 1),
  • 5 A at 30 VDC with resistive load,
  • 0.15 A max. at 125 VDC with resistive load,
  • 0.1A max. at 125 VDC with L/R of 7 ms.

The minimum applicable load is 10 mA at 5 VDC (P reference value).

Contact materials: Ag-alloy

(Recommended fuse: BLN5 (Littelfuse) or 0216005MXEP)

Ambient temperature

Operating: -20 to 60°C (with no icing)

Storage: -40 to 70°C (with no icing)

Accuracy of operating time

±1% of FS max. (±1% ±10 ms max. at 1.2 s range)

±1% of FS max.

±1% of FS max. (±1% ±10 ms max. at 1.2 s range)

Setting error

±10% of FS ±0.05 s max.

Influence of voltage

±0.5% of FS max. (±0.5% ±10 ms max. at 1.2 s range)

±0.5% of FS max.

±0.5% of FS max. (±0.5% ±10 ms max. at 1.2 s range)

Influence of temperature

±2% of FS max. (±2% ±10 ms max. at 1.2 s range)

±2% of FS max.

±2% of FS max. (±2% ±10 ms max. at 1.2 s range)

Life expectancy

Mechanical: 10 million operations min. (under no load at 1,800 operations/h)

Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)

Degree of protection

IP30 (Terminal block: IP20)

Size in mm (H × W × D)

100×17.5×90


1. According to OMRON investigation in October 2015.

2. Based on OMRON comparison (excluding the H3DT-H).

3. Certification is pending for DNV GL.

4. Star set time (t1) range. Star-Delta transfer time (t2): Select from 0.05, 0.1, 0.25, or 0.5 s

5. When using a 24 VDC power supply voltage, there will be an inrush current of approximately 0.5 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as a sensor.

6. DC ripple: 20% max.

7. The power consumption is the value after the timer times out.

4. Star set time (t1) range. Star-Delta transfer time (t2): Select from 0.05, 0.1, 0.25, or 0.5 s

5. When using a 24 VDC power supply voltage, there will be an inrush current of approximately 0.5 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as a sensor.

6. DC ripple: 20% max.

7. The power consumption is the value after the timer times out.

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

+ 45 43 44 00 11
Contact us

Kontakt mig H3DT

h3dt prod

Hvis du ønsker at blive kontaktet af vores Salgsingeniør i dit område for at få mere information, så udfyld venligst formularen nedenfor: Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Text area error notification

Checkbox error notification

Checkbox error notification

Tak for indsendelsen af din forespørgsel. Vi vil vende tilbage med svar så hurtigt som muligt.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download
+ 45 43 44 00 11
+ 45 43 44 00 11
Request quotation
Request quotation

Tilbud på H3DT

Med denne formular kan du bestille et tilbud på et eller flere af vores produkter. Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.

h3dt prod

Personlige detaljer

H3DT

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Tilbyde detaljer

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Tak for din forespørgsel. Vi vender tilbage med de ønskede oplysninger så hurtigt som muligt.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download
Request quotation
Request quotation

Downloads