DST-ID

Funktioner

DeviceNet Safety I/O-klemmerække DST-ID

DeviceNet Safety-indgangsklemmen DST-ID har 12 indgange til sikkerhedssignalerne. Fire testimpulsudgange sikrer detektering af crosstalk og kortslutninger.

  • De flytbare fjederklemmer sikrer nem installation
  • 12 indgange til sikkerhedssignaler
  • 4 testimpulsudgange til detektering af crosstalk og kortslutninger
  • Status-LED'er til avanceret diagnosticering
  • Håndterer både standard- og sikkerhedsindgange
Specifikationer & bestillingsinfo

Ordering information

 

 

Appearance

Appearance description

Order code

Input terminal

12 PNP inputs

4 Test outputs

Removable cage clamp terminals

DST1-ID12SL-1

Mixed I/O terminal

8 PNP inputs

8 PNP outputs

4 Test outputs

Removable cage clamp terminals

DST1-MD16SL-1

Mixed I/O terminal

4 PNP inputs

4 relay outputs (4×2-single pole)

4 Test outputs

Removable cage clamp terminals

DST1-MRD08SL-1

Specifications

General specifications

DeviceNet communications power supply voltage

11 to 25 VDC
(supplied from communications connector)

Unit power supply voltage

20.4 to 26.4 VDC (24 VDC -15% +10%)

I/O power supply voltage

Consumption
current

Communications power supply

DST1-ID12SL-1/MD16SL-1: 100 mA

DST1-MRD08SL-1: 110 mA

Mounting method

35-mm DIN track

Ambient operating temperature

-10°C +55°C

Ambient storage temperature

-40°C +70°C

Degree of protection

IP20 (IEC 60529)

Weight

DST1-ID12SL-1/MD16SL-1: 420 g

DST1-MRD08SL-1: 600 g

Safety input specifications

Input type

Sinking inputs (PNP)

ON voltage

11 VDC min. between each input terminal and G1

OFF voltage

5 VDC max. between each input terminal and G1

OFF current

1 mA max.

Input current

6 mA

Safety output specifications

Output type

Sourcing outputs (PNP)

Rated output current

0.5 A max. per output

Residual voltage

1.2 V max. between each output terminal and V1

Test output specifications

Output type

Sourcing outputs (PNP)

Rated output current

0.7 A max. per point

Residual voltage

1.2 V max. between each output terminal and V0

Safety output specifications for relay outputs

Relays

G7SA-2A2B, EN 50205 class A

Minimum applicable load

1 mA at 5 VDC

Rated load for a resistive load

240 VAC: 2 A, 30 VDC: 2 A

Rated load for an inductive load

2 A at 240 VAC (cos φ = 0.3),

1 A at 24 VDC

Mechanical life expectancy

5,000,000 operations min.
(switching frequency of 7,200 operations/h)

Electrical life expectancy

100,000 operations min. (at rated load and
switching frequency of 1,800 operations/h)

 

Safety I/O terminals

DST1-ID12SL-1

DST1-MD16SL-1

DST1-MRD08SL-1

 

Har du et spørgsmål?

Vi er klar til at hjælpe.

Kontakt os

Abonnér på produktopdateringer

Nyhedsbreve om produktinnovationer, løsninger og serviceydelser direkte i din indbakke.

Tak for din tilmelding til Omrons nyhedsbrev. Du vil i løbet af kort tid modtage en e-mail fra os, som indeholder et link hvormed du aktiverer din tilmelding til nyhedsbrevet. Denne metode anvendes i henhold til lovgivningen for at sikre, at ingen kan misbruge din e-mail addresse.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Produktdokumentation

Download datablade, manualer og brochurer.

Gennemse downloadcenter

Kurser

Bliv uddannet af vores bedste ingeniører. Fra begynder til udvidet niveau.

Se tilgængelige kurser