Log på

Please use more than 6 characters. Forgot your password? Click here to reset.

Skift adgangskode

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Registrering

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Tak, fordi du registrerede dig hos Omron

Der er sendt en e-mail, som færdiggør oprettelsen af din konto, til

Gå tilbage til webstedet

få direkte adgang

Udfyld dine oplysninger nedenfor for at få direkte adgang til indhold på denne side

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Tak for din interesse

Du har nu adgang til G7SA

Der er sendt en bekræftelses-e-mail til

Fortsæt til side

Du skal eller få direkte adgang for at downloade dette dokument

G7SA

Funktioner

Relæer med tvangsstyrede kontakter

Den kompakte G7SA-relæfamilie med tvangsstyrede kontakter fås som fire- eller sekspolet udgave med forskellige kontaktkombinationer samt forstærket isolering. Terminaler er placeret iht. PCB-layout. Kan loddes direkte på en PCB eller anvendes sammen med P7SA-stikkene.

  • Tvangsstyrede kontakter
  • Overholder EN 50205
  • 6 A ved 240 VAC og 6 A ved 24 VDC ved resistive belastninger
  • Forstærket isolering mellem indgange, udgange og poler
  • Relæerne fås i 4- og i 6-polet udgave
  • Stik fås med push-in-teknologi
Specifikationer & bestillingsinfo

Ordering information

Relays with forcibly guided contacts

Type

Sealing

Poles

Contacts

Rated voltage

Order code

Standard

Flux-tight

4 poles

3PST-NO, SPST-NC

24 VDC1

G7SA-3A1B

DPST-NO, DPST-NC

G7SA-2A2B

6 poles

5PST-NO, SPST-NC

G7SA-5A1B

4PST-NO, DPST-NC

G7SA-4A2B

3PST-NO, 3PST-NC

G7SA-3A3B

Sockets

Mounting

Terminal type

LED indicator

Poles

Coil rated voltage

Order code

Front-
mounting

Push-In Plus terminals

Yes

4 poles

24 VDC

P7SA-10F-ND-PU

6 poles

P7SA-14F-ND-PU

Screw terminals

Yes

4 poles

P7SA-10F-ND

6 poles

P7SA-14F-ND

No

4 poles

P7SA-10F

6 poles

P7SA-14F

Back-
mounting

PCB terminals

No

4 poles

P7SA-10P

6 poles

P7SA-14P

Specifications

Coil

Rated voltage

Rated current

Coil resistance

Must-operate voltage

Must-release voltage

Max. voltage

Power consumption

24 VDC

4 poles: 15 mA

6 poles: 20.8 mA

4 poles: 1,600 Ω
6 poles: 1,152 Ω

75% max. (V)

10% min. (V)

110% (V)

4 poles: Approx. 360 mW
6 poles: Approx. 500 mW

Note: Refer to datasheet for details

Contacts

Load

Resistive load (cos φ = 1)

Rated load

6 A at 250 VAC, 6 A at 30 VDC

Rated carry current

6 A

Max. switching voltage

250 VAC, 125 VDC

Max. switching current

6 A

Max. switching capacity (reference value)

1,500 VA, 180 W

Relays with forcibly guided contacts

Contact resistance

100 mΩ max. (The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.)

Operating time 2

20 ms max.

Response time 1

10 ms max.
(The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.)

Release time 1

20 ms max.

Insulation resistance

100 MΩ min. (at 500 VDC) (The insulation resistance was measured with a 500 VDC megger at the same places that the dielectric strength was
measured.)

Dielectric strength 3 4

Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min
(2,500 VAC between poles 3-4 in 4-pole Relays or poles 3-5, 4-6, and 5-6 in 6-pole Relays.)

Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min

Durability

Mechanical

10,000,000 operations min. (at approx. 36,000 operations/hr)

Electrical

100,000 operations min. (at the rated load and approx. 1,800 operations/hr)

Min. permissible load5

5 VDC, 1 mA (reference value)

Ambient temperature 6

Operating: −40 to 85°C (with no icing or condensation)

Ambient humidity

Operating: 35 to 85%

Approved standards

EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14

Note: The values listed above are initial values.

 

Please check Omron in the Internet for updated information on product reliability data and the SISTEMA libraries: http://industrial.omron.eu/safety


1. 12 VDC, 21 VDC, 48 VDC are available on request.
2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.
3. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64.
4. When using a P7SA socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min.
5. Min. permissible load is for a switching frequency of 300 operations/min.
6. When operating at a temperature between 70°C and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree above 70°C.
1. 12 VDC, 21 VDC, 48 VDC are available on request.
2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.
3. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64.
4. When using a P7SA socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min.
5. Min. permissible load is for a switching frequency of 300 operations/min.
6. When operating at a temperature between 70°C and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree above 70°C.

Har du et spørgsmål?

Vi er klar til at hjælpe.

Kontakt os

Abonnér på produktopdateringer

Nyhedsbreve om produktinnovationer, løsninger og serviceydelser direkte i din indbakke.

Tak for din tilmelding til Omrons nyhedsbrev. Du vil i løbet af kort tid modtage en e-mail fra os, som indeholder et link hvormed du aktiverer din tilmelding til nyhedsbrevet. Denne metode anvendes i henhold til lovgivningen for at sikre, at ingen kan misbruge din e-mail addresse.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Produktdokumentation

Download datablade, manualer og brochurer.

Gennemse downloadcenter

Kurser

Bliv uddannet af vores bedste ingeniører. Fra begynder til udvidet niveau.

Se tilgængelige kurser