Login

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Register

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Thank you for your interest

You now have access to G9SE

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

G9SE

G9SE

Slim-size safety relay unit family

G9SE-family offers compact units for E-Stop, door and safety monitoring applications . Modules with two or four safety contacts and OFF-delay timing are available on slim-size housing.

  • Simple front side wiring using screw-less terminals.
  • 17.5 or 22.5 mm width to save mounting space
  • 15ms Max. response time
  • Safe OFF delay function up to PLe
  • Certification for lift standards EN 81-1, EN 81-2
  • Up to Ple according to EN ISO 13849-1 and SIL 3 according to EN 61508

Specifications & ordering info

Ordering information

Safety outputs

Auxiliary outputs 1

Max. OFF-delay time 2

Rated voltage

Order code

Instantaneous

OFF-delayed

DPST-NO

-

1 PNP transistor output

-

24 VDC

G9SE-201

4PST-NO

G9SE-401

DPST-NO

DPST-NO

5 s

G9SE-221-T05

DPST-NO

DPST-NO

30 s

G9SE-221-T30

Specifications

Ratings

Power Input

Item

G9SE-201

G9SE-401

G9SE-221-T _

Rated supply voltage

24 VDC

Operating voltage range

-15% to 10% of rated supply voltage

Rated power consumption3

3 W max.

4 W max.

 

Outputs

Item

G9SE-201

G9SE-401

G9SE-221-T _

Safety output

OFF-delayed safety output

Contact output

250 VAC 5 A 30 VDC 5 A (resistance load)

Auxiliary output

PNP transistor output Load current: 100 mA DC max.

 

Characteristics

Item

G9SE-201

G9SE-401

G9SE-221-T _

Operating time (OFF to ON state) 4

100 ms Max. 5

Response time (ON to OFF state) 6

15 ms Max.

Inputs

Input current

5 mA Min.

ON voltage

11 VDC Min.

OFF voltage

5 VDC Max.

OFF current

1 mA Max.

Maximum cable length

100 m Max.

Reset input time

250 ms Min.

Contact outputs

Contact resistance 7

100 m Ω

Mechanical durability

5,000,000 operations Min.

Electrical durability

50,000 operations Min.

Switching specification Inductive load

(IEC/EN60947-5-1)

AC15: 240 VAC 2 A

DC13: 24 VDC 1.5 A

Minimum applicable load

24 VDC 4 mA

Conditional short-circuit current

(IEC/EN60947-5-1)

100A 8

Surrounding air temperature

-10 to 55 ° C (No freezing or condensation)


1. PNP transistor output

2. The OFF-delay time can be set in 16 steps as follows:
T05: 0/0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/1/1.5/2/2.5/3/4/5 s
T30: 0/1/2/4/5/6/7/8/9/10/12/14/16/20/25/30 s

3. Power consumption of loads not included.

4. The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not including bounce time.

5. This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..

6. The response time is the time it takes for the safety main contact to open after the safety input is turned OFF. Includes bouncetime.

7. This is initial value using the voltage-drop method with 1 A at 5 VDC.

8. Use an 8 A fuse that conforms to IEC 60127 as a short-circuit protection device. This fuse is not included with the G9SE.

1. PNP transistor output

2. The OFF-delay time can be set in 16 steps as follows:
T05: 0/0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/1/1.5/2/2.5/3/4/5 s
T30: 0/1/2/4/5/6/7/8/9/10/12/14/16/20/25/30 s

3. Power consumption of loads not included.

4. The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not including bounce time.

5. This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..

6. The response time is the time it takes for the safety main contact to open after the safety input is turned OFF. Includes bouncetime.

7. This is initial value using the voltage-drop method with 1 A at 5 VDC.

8. Use an 8 A fuse that conforms to IEC 60127 as a short-circuit protection device. This fuse is not included with the G9SE.

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

+ 45 43 44 00 11
Contact us

Kontakt mig G9SE

g9se product prod

Hvis du ønsker at blive kontaktet af vores Salgsingeniør i dit område for at få mere information, så udfyld venligst formularen nedenfor: Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Text area error notification

Checkbox error notification

Checkbox error notification

Tak for indsendelsen af din forespørgsel. Vi vil vende tilbage med svar så hurtigt som muligt.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download
+ 45 43 44 00 11
+ 45 43 44 00 11
Request quotation
Request quotation

Tilbud på G9SE

Med denne formular kan du bestille et tilbud på et eller flere af vores produkter. Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.

g9se product prod

Personlige detaljer

G9SE

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Tilbyde detaljer

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Tak for din forespørgsel. Vi vender tilbage med de ønskede oplysninger så hurtigt som muligt.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download
Request quotation
Request quotation

Downloads