S8M
Multi circuit protector
The S8M turns your machine directly into UL Class 2 compliant, maximum tripping current is 3,8A per channel (adjustable). This unit controls up to 4 circuits. On top of this you will get startup / shutdown –sequence control, display and alarm functions, like voltage, output current, runtime, and over temperature and external reset. These functions can be set by using the front buttons or with the free support tool software. These settings can be protected.
- 4 circuit protection up-to 4A per channel
- UL Class 2 (max. 3.8A)
- Emergency stop by external signal
- Optimize use of available power through Start-up sequence
- Maintenance Control
Specifications & ordering info
Ordering information
Note: Model S8M-CP04-R available on request. Please contact your Omron representative for special request.
Specifications
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakt mig S8M
Tak for indsendelsen af din forespørgsel. Vi vil vende tilbage med svar så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
DownloadTilbud på S8M
Med denne formular kan du bestille et tilbud på et eller flere af vores produkter. Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.
Tak for din forespørgsel. Vi vender tilbage med de ønskede oplysninger så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
DownloadFeatures
Software
S8M Support Software
With this support software you can configure your S8M settings in a very easy way. The following settings can be configured:
- Common setting alarms for under-voltage, over-voltage, temperature and running time.
- Your branch values like tripping type, over-current alarm value, startup sequence and shutdown sequence.
In addition you can also monitor your S8M with this support software giving you direct access to your power supplies application conditions:
- You can monitor all values and you can get a status overview. You get the actual input voltage, the current per branch output plus the peak current (which you can clear) and the total current consumption.
- You can measure the internal temperature, running time, connection status and the startup / shutdown sequence.
- You can control each branch output by tripping or connection through the software.
Free download
You can download the S8M Support Software for free from the "Downloads - Software tools" tab.