Login

Please use more than 6 characters. Forgot your password? Click here to reset.

Change password

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Register

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Thank you for your interest

You now have access to G3PA

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

G3PA

  • CAD Bibliotek
  • G3PA Solid State Relays Datablad
  • Thank you for downloading the G3PA Solid State Relays Datablad

    Download again

    Did you know that 4 out of 5 distributors buy this product in a bundle?

    There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

    Read more
Features

Solid State Relays with exchangeable power cartridge

Optimum design of the heat sink has contributed to the downsizing of this product. The power element cartridges of the G3PA are easily replaceable for easy maintenance. G3PA can be mounted on a DIN-rail or using screws.

  • 20-60 A output current
  • 24-480 VAC output voltages
  • Applicable with 3-phase loads
  • Replaceable power element cartridges
Specifications & ordering info

Ordering information

Rated output load

Zero cross function

Rated input voltage

Operating voltage range

Input
current impedance

Voltage level

Size in mm
(H×W×D)

Order code

Must operate voltage

Must release voltage

24 to 240 VAC

40 A

Yes

5 to 24 VDC

4 to 30 VDC

7 mA max.

4 VDC max.

1 VDC min.

100×47×100

G3PA-240B-VD DC5-24

60 A

 

100×110×100

G3PA-260B-VD DC5-24

40 A

 

24 VAC

19.2 to 26.4 VAC

1.4 kΩ ±20%

19.2 VAC max.

4.8 VAC min.

100×47×100

G3PA-240B-VD AC24

60 A

 

100×110×100

G3PA-260B-VD AC24

180 to 400 VAC

20 A

 

12 to 24 VDC

9.6 to 30 VDC

7 mA max.

9.2 VDC max.

1 VDC min.

100×37×100

G3PA-420B-VD DC12-24

30 A

 

100×47×100

G3PA-430B-VD DC12-24

200 to 480 VAC

20 A

 

100×37×100

G3PA-420B-VD-2 DC12-24

30 A

 

100×47×100

G3PA-430B-VD-2 DC12-24

50 A

 

100×110×100

G3PA-450B-VD-2 DC12-24

Accessories

 

Replacement parts: Power device cartridges

Load voltage range

Carry current

Applicable SSR

Order code

19 to 264 VAC

40 A

G3PA-240B-VD DC5-24

G32A-A40-VD DC5-24

G3PA-240B-VD AC24

G32A-A40-VD AC24

60 A

G3PA-260B-VD DC5-24

G32A-A60-VD DC5-24

G3PA-260B-VD AC24

G32A-A60-VD AC24

150 to 440 VAC

20 A

G3PA-420B-VD DC12-24

G32A-A420-VD DC12-24

30 A

G3PA-430B-VD DC12-24

G32A-A430-VD DC12-24

180 to 528 VAC

20 A

G3PA-420B-VD-2 DC12-24

G32A-A420-VD-2 DC12-24

30 A

G3PA-430B-VD-2 DC12-24

G32A-A430-VD-2 DC12-24

50 A

G3PA-450B-VD-2 DC12-24

G32A-A450-VD-2 DC12-24

 

G32A-D__ enables 2 line switching of 3 phase configurations

Current flow

Applicable SSR

Order code

20 A

G3PA-420B-VD, G3PA-420B-VD-2

G32A-D20

30 A

G3PA-430B-VD, G3PA-430B-VD-2,
G3PA-240B-VD, G3PA-240BL-VD

G32A-D40

40 A

Specifications

Isolation

Phototriac coupler

Indicator

Yes

Ambient temperature

Operating: −30 to 80°C

Load voltage range

200 to 480 VAC: 180 to 528 VAC

24 to 240 VAC: 19 to 264 VAC

180 to 400 VAC: 150 to 440 VAC

Output ON drop

1.6 V (RMS) max.

Operate time

0.5 of load power source cycle + 1 ms max. (DC input, -B models)

1.5 of load power source cycle + 1 ms max. (AC input)
1 ms max. (-BL models)

Release time

0.5 of load power source cycle + 1 ms max. (DC input)

1.5 of load power source cycle + 1 ms max. (AC input)

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Tak for din tilmelding til Omrons nyhedsbrev. Du vil i løbet af kort tid modtage en e-mail fra os, som indeholder et link hvormed du aktiverer din tilmelding til nyhedsbrevet. Denne metode anvendes i henhold til lovgivningen for at sikre, at ingen kan misbruge din e-mail addresse.

Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses