MX2
Born to Drive Machines
Specifically created for your application, the MX2 was developed to harmonise advanced motor and machine control. Thanks to its advanced design and algorithms, the MX2 provides smooth control down to zero speed, plus precise operation for cyclic operations and torque control capability in open loop.
- High starting torque: 200% at 0.5 Hz
- Torque control in open loop vector
- Double rating VT 120%/1 min and CT 150%/ 1 min
- IM & PM motor control
- Safety conforming to ISO13849-1 Category
- 3 performance level PLD
- Built-in Logic programming
- Positioning functionality
- Integrated at Omron machine Automation solution
- Fieldbus communications: EtherCAT, Modbus, DeviceNet, Profibus, CompoNet, MECHATROLINK-II and EtherNet/IP
- Ratings: 200 V single-phase from 0.1 to 2.2 kW, 200 V three-phase from 0.1 to 15.0 kW, 400 V three-phase from 0.4 to 15.0 kW.
Specifications & ordering info
Produkt | Drive control method | Drive supply voltage | Max. motor output at constant torque | Max. motor output at variable torque | Built in EMC filter | Degree of protection (IP) | Finless type | Compatible motor type | Regenerative solutions | Communication port(s) | Communication option(s) | Description | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.1 kW | 0.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.1/0.2 kW (ND/LD), 1.0/1.2 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.2 kW | 0.4 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.2/0.4 kW (ND/LD), 1.6/1.9 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.4 kW | 0.55 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.4/0.55 kW (ND/LD), 3.0/3.5 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.1 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.75/1.1 kW (ND/LD), 5.0/6.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 1.5 kW | 2.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 1.5/2.2 kW (ND/LD), 8.0/9.6 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 2.2 kW | 3 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 2.2/ 3.0 kW (ND/LD), 11.0/12.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 4 kW | 5.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX inverter drive, 3.7/5.5 kW (HD/ND), 17.5/19.6 A (HD/ND), 200 VAC, 3~ input, sensorless vector, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 4 kW | 5.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 3.7/5.5 kW (ND/LD), 17.5/19.6 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 5.5 kW | 7.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 5.5/7.5 kW (ND/LD), 25.0/30.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 7.5 kW | 11 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 7.5/11 kW (ND/LD), 33.0/40.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 11 kW | 15 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 11/15 kW (ND/LD), 47.0/56.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 15 kW | 18.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 15/18.5 kW (ND/LD), 60.0/69.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.4 kW | 0.75 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.4/0.75 kW (ND/LD), 1.8/2.1 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.4 kW | 0.75 kW | No | IP20 | Yes | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | 3G3MX2 inverter drive, 0.4/0.75 kW (HD/ND), 1.8/2.1 A (HD/ND), 400 VAC, 3~, sensorless vector, w/o heatsink, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.75 kW | 1.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.75/1.5 kW (ND/LD), 3.4/4.1 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.75 kW | 1.5 kW | No | IP20 | Yes | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | 3G3MX2 inverter drive, 0.75/1.5 kW (HD/ND), 3.4/4.1 A (HD/ND), 400 VAC, 3~, sensorless vector, w/o heatsink, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX inverter drive, 1.5/2.2 kW (HD/ND), 4.8/5.4 A (HD/ND), 400 VAC, 3~, sensorless vector, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 1.5/2.2 kW (ND/LD), 4.8/5.4 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | No | IP20 | Yes | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | 3G3MX2 inverter drive, 1.5/2.2 kW (HD/ND), 4.8/5.4 A (HD/ND), 400 VAC, 3~, sensorless vector, w/o heatsink, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 2.2 kW | 3 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 2.2/3.0 kW (ND/LD), 5.5/6.9 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakt mig MX2
Tak for indsendelsen af din forespørgsel. Vi vil vende tilbage med svar så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
DownloadTilbud på MX2
Med denne formular kan du bestille et tilbud på et eller flere af vores produkter. Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.
Tak for din forespørgsel. Vi vender tilbage med de ønskede oplysninger så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
DownloadTechnical support
Technical Support
Videos
Relaterede produkter
-
One software tool for inverters & servos
-
One software for your automation system
-
Winder / Unwinder dedicated functionality
-
Pump Sequencer dedicated functionality