RX2
Save energy and maximize performance with versatile inverter
This high performance inverter offers the same usability as the previous model and delivers improved usability: more efficient, easier, and faster.
- High starting torque in open loop: 200% at 0.3 Hz, Full torque at 0 Hz in closed loop
- Sensor-less and vector closed-loop control
- Triple rating: VLD 110%/1min, LD 120%/1 min and ND 150%/1 min
- Built-in EMC filter, logic programming and application functionality
- Positioning functionality
- Safe Torque Off (STO) according to EN ISO 13849-1:2008 (Safety Category 3/PLd) and IEC 60204-1 Stop Category 0
- Communication options: Modbus, Modbus TCP
- Regenerative solutions as option
- CE, CULus, RoHS
- Ratings: 200 V class three-phase 0.4 to 55 kW / 400 V three-phase 0.75 to 132 kW
Specifications & ordering info
Produkt | Inverter control method | Drive supply voltage | Max. motor output at constant torque (HD) | Max. motor output at variable torque (ND) | Built in EMC filter | Degree of protection (IP) | Finless type | Compatible motor type | Regenerative solutions | Communication port(s) | Communication option(s) | Description |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.4 kW | 0.75 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 4,4 A / 0,75 kW, LD: 3,7 A / 0,75 kW, ND: 3,2 A / 0,4 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 8,0 A / 1,5 kW, LD: 6,3 A / 1,5 kW, ND: 5,0 A / 0,75 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 1.5 kW | 2.2 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 10,4 A / 2,2 kW, LD: 9,4 A / 2,2 kW, ND: 8,0 A / 1,5 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 2.2 kW | 3.7 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 15,6 A / 3,7 kW, LD: 12 A / 3,7 kW, ND: 11 A / 2,2 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 3.7 kW | 5.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 22,8 A / 5,5 kW, LD: 19,6 A / 5,5 kW, ND: 17,5 A / 3,7 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 5.5 kW | 7.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 33 A / 7,5 kW, LD: 30 A / 7,5 kW, ND: 25 A / 5,5 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 7.5 kW | 11 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 46 A / 11 kW, LD: 40 A / 11 kW, ND: 32 A / 7,5 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 11 kW | 15 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 60 A / 15 kW, LD: 56 A / 15 kW, ND: 46 A / 11 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 15 kW | 18.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 80 A / 18,5 kW, LD: 73 A / 18,5 kW, ND: 64 A / 15 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 18.5 kW | 22 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 93 A / 22 kW, LD: 85 A / 22 kW, ND: 76 A / 18,5 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 22 kW | 30 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 124 A / 30 kW, LD: 113 A / 30 kW, ND: 95 A / 22 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 30 kW | 37 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 153 A / 37 kW, LD: 140 A / 37 kW, ND: 122 A / 30 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 37 kW | 45 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 185 A / 45 kW, LD: 169 A / 45 kW, ND: 146 A / 37 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 45 kW | 55 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 229 A / 55 kW, LD: 210 A / 55 kW, ND: 182 A / 45 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 55 kW | 75 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 200 V, VLD: 295 A / 75 kW, LD: 270 A / 75 kW, ND: 220 A / 55 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 0.75 kW | 1.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 400 V, VLD: 4,1 A / 1,5 kW, LD: 3,1 A / 1,5 kW, ND: 2,5 A / 0,75 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 400 V, VLD: 5,4 A / 2,2 kW, LD: 4,8 A / 2,2 kW, ND: 4,0 A / 1,5 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 2.2 kW | 3.7 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 400 V, VLD: 8,3 A / 3,7 kW, LD: 6,7 A / 3,7 kW, ND: 5,5 A / 2,5 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 3.7 kW | 5.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 400 V, VLD: 12,6 A / 5,5 kW, LD: 11,1 A / 5,5 kW, ND: 9,2 A / 3,7 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. | |
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 5.5 kW | 7.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | Inverter RX2, 400 V, VLD: 17,5 A / 7,5 kW, LD: 16 A / 7,5 kW, ND: 14,8 A / 5,5 kW, open/closed loop vector, built-in filter, max. output freq. 590Hz, IP20. |
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakt mig RX2

Tak for indsendelsen af din forespørgsel. Vi vil vende tilbage med svar så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
DownloadTilbud på RX2
Med denne formular kan du bestille et tilbud på et eller flere af vores produkter. Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.

Tak for din forespørgsel. Vi vender tilbage med de ønskede oplysninger så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
DownloadFeatures
Application customized
The RX2 Inverter can perform simple sequence control programmed for using support software CX-Drive. Crane control, tension control and other large-scale processes that require fast control speeds can be configured without a PLC, optimizing costs.
PM Motor Control
The RX2 Series can control permanent magnet motors (PM motors) as well as induction motors. Autotuning maximizes PM motor performance and helps saving energy.
Safety embedded
The RX2 Series features Safe Torque Off (STO) as a standard, to meet your machine safety needs.
Certified standards: IEC 61800-5-2:2016 STO SIL3 ISO 13849-1:2015 Cat.4 PLe
EtherCAT® - Coming soon
The EtherCAT option is available. Connect the RX2 inverters with the NX/NJ Machine Automation Controller to improve development and production productivity. Note: the EtherCAT unit will be coming soon.