
ZX-T
Smart Contact measurement sensor
ZX-T is ideal for applications where the target object may contain oil deposits or other micro-structures. In this case contact measurement is the most reliable way.
- Modular platform concept for different sensing technologies
- Air-retracting types for automated inspection
- Multipoint measurement with up to 8 sensors
- Pressing force alarm prevents malfunction
- Strong ball bearing structure assures long life time
Specifications & ordering info
Ordering information

Sensors
Sensor heads
Note: The resolution refers to the minimum value that can be read when a ZX-TDA_1 amplifier unit is connected.
Amplifier units
Accessories (order separately)
Calculating unit
ZX-series communications interface unit
SmartMonitor sensor setup tool for Personal Computer connection
, | |
Cables with connectors on both ends (for extension)
*
undefined
* Robot cable models are also available. The model numbers are ZX-XC_R.
Preamplifier mounting brackets
Actuators
Measuring ordinary flat surfaces (standard |
![]() |
||||
![]() |
|||||
![]() |
|||||
![]() |
|||||
![]() |
|||||
Mounting D5SN-TN1/-TF1 or commercially |
![]() |
Note:
Replacement possible
Conversion adapter required
Specifications

Amplifier units
Sensor heads
9
9.
These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
|
||||
Operating: 0 to 50°C, storage: - 15 to 60°C (with no icing or condensation) |
||||
Operating and storage: 35% to 85% (with no icing or condensation) |
||||
Instruction manual, preamplifier mounting brackets (ZX-XBT1) |
1.
When using the ZX-TDA11/41 with the SmartMonitor, either the ZX-SFW11EV3 or the
ZX-SW11EV3 SmartMonitor must be used. Earlier versions cannot be used.
3.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1).
4. The output can be switched between a current output and voltage output using a switch on the bottom of the amplifier unit.
7. The resolution is given as the minimum value that can be read when a ZX-TDA_1 amplifier unit is connected. This value is taken 15 minutes after turning ON the power with the average number of operations set to 256.
9. These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
1.
When using the ZX-TDA11/41 with the SmartMonitor, either the ZX-SFW11EV3 or the
ZX-SW11EV3 SmartMonitor must be used. Earlier versions cannot be used.
3.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1).
4. The output can be switched between a current output and voltage output using a switch on the bottom of the amplifier unit.
7. The resolution is given as the minimum value that can be read when a ZX-TDA_1 amplifier unit is connected. This value is taken 15 minutes after turning ON the power with the average number of operations set to 256.
9. These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakt mig ZX-T

Tak for indsendelsen af din forespørgsel. Vi vil vende tilbage med svar så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
DownloadTilbud på ZX-T
Med denne formular kan du bestille et tilbud på et eller flere af vores produkter. Venligst udfyld alle de felter der er markeret med *. Dine personlige oplysninger vil blive håndteret fortroligt.

Tak for din forespørgsel. Vi vender tilbage med de ønskede oplysninger så hurtigt som muligt.
Vi har desværre tekniske problemer. Din formular er ikke modtaget. Vi undskylder og beder dig om at prøve igen senere. Detaljer: [details]
Download